AconityCONTROL
Machine DESCRIPTION
Control the Process – Not the Parameters
In a furnace, nobody prescribes the current. You define the temperature and the time – the furnace handles the rest. In additive manufacturing, this is still different: laser power, scan speed and hatch distance are set as fixed values and remain constant throughout the entire build process, regardless of what is actually happening in the melt pool.
AconityCONTROL fundamentally changes this principle. Instead of prescribing rigid laser power values, you define an emission setpoint. The controller adjusts the laser power in real time, on-the-fly, layer by layer, part by part, layer by layer, vector by vector. The process responds to what it measures, not to what was assumed beforehand.
The result: Thermal process management shifts from assumption to measurement. From rigid parameters to adaptive control.
The Replicator – Reproducibility through Thermal Identity
Destructive testing is indispensable in aerospace and energy technology. But what happens after the test? In conventional LPBF manufacturing, the next part is built with the same parameters, but not necessarily with the same thermal history. Local geometry differences, heat accumulation or varying powder bed conditions mean that identical parameters do not guarantee identical results.
AconityCONTROL makes the decisive difference: By controlling to a defined emission setpoint, it is not the parameter that is reproduced, but the process response. This means: If a destructively tested part meets the requirements, the next part can be exactly replicated by fully meeting the tested parts emission fingerprint.
The path from qualification to series production becomes shorter, more comprehensive and reachable within no time.
Technical SPECIFICATIONS
AconityCONTROL is fully implemented in the AconitySTUDIO software environment, allowing easy configuration of the control parameters which may be set for each individual part. Additionally, AconityCONTROL may be configured for operation with customer specific sensors for increased flexibility.
- Sampling rate
- 100 kHz
- Response time
- ~ 20 µs
- Signal input
- 0–5 V, 0–10 V, 4–20 mA
- Signal output
- 0–10 V
- Required sensor
- Highspeed Pyrometry
- Required software
- AconitySTUDIO (≥ 3.2)
- Data output
- PCD file (Position, Sensor Signal, Laser Status, Controller Output)